Abst:Installation specification for barrier-free handrails in aisle corridors1. Handrails with a height of 0.85m should be installed on both sides of ramp...
Installation specification for barrier-free handrails in aisle corridors
1. Handrails with a height of 0.85m should be installed on both sides of ramps, steps and stairs; when two layers of handrails are installed, the height of the lower handrails should be 0.65m;
2. The distance between the inside of the handrail and the wall should be 40-50mm;
3. The handrail should be installed firmly and the shape is easy to grasp.
Installation specifications for barrier-free handrails, bathroom handrails and
safety grab bars in toilets and public toilets
1. Safety grab bars should be provided 50mm from both sides and the front edge of the wash basin;
2. Safety grab bars with a width of 0.60-0.70m and a height of 1.20m should be provided on both sides and above the urinal;
3. The height of the toilet is 0.45m, and a horizontal grab bar with a height of 0.70m should be installed on both sides, and a vertical grab bar with a height of 1.40m should be installed on one side of the wall;
4. The diameter of the barrier-free handrail should be 30-40mm;
5. The inner side of the barrier-free handrail should be 40mm away from the wall;
6. The grab bar should be installed firmly.